Related Experiment Video
Updated: Feb 23, 2026

12:54
Implementation of a Coherent Anti-Stokes Raman Scattering CARS System on a Ti:Sapphire and OPO Laser Based Standard Laser Scanning Microscope
Published on: July 17, 2016
11.7K
Resonance effects in first- and second-order Raman scattering from AlAs
Summary
No abstract available in PubMed .
Related Concept Videos
Raman Spectroscopy: Overview
1.9K
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
1.9K
¹H NMR: Interpreting Distorted and Overlapping Signals
1.6K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.6K
Double Resonance Techniques: Overview
805
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
805
Raman Spectroscopy Instrumentation: Overview
1.4K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.4K
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones
5.7K
In aldehydes, the hydrogen atom connected to the carbonyl carbon helps distinguish aldehydes from other carbonyl compounds using ¹H NMR spectroscopy. The closeness of aldehydic hydrogen to the electrophilic carbonyl carbon highly deshields the hydrogen atom causing its signal to appear around 10 ppm in the ¹H NMR spectra. α hydrogens split the aldehydic proton signal, which helps identify the number of α hydrogens in the molecule. For instance, one α hydrogen creates a...
5.7K
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
7.5K
Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the...
7.5K

