Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A new multiangle goniometer.

S J McCulley1

  • 1Department of Plastic & Reconstructive Surgery, University of Cape Town, Groote Schuur Hospital, South Africa.

Annals of Plastic Surgery
|February 24, 1999
PubMed
Summary

A new goniometer measures multiple hand joint angles simultaneously, simplifying and speeding up patient hand movement assessments. This tool aids in creating accurate visual records of joint mobility.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Oncoplastic and reconstructive breast surgery in the elderly.

The British journal of surgery·2015
Same author

Qualitative mammographic findings and outcomes of surveillance mammography after partial breast reconstruction with an autologous flap.

Journal of surgical oncology·2014
Same author

Therapeutic mammaplasty.

Journal of surgical oncology·2014
Same author

Transverse Upper Gracilis (TUG) flap for volume replacement in breast conserving surgery for medial breast tumours in small to medium sized breasts.

Journal of plastic, reconstructive & aesthetic surgery : JPRAS·2011
Same author

Magnetic resonance angiography in preoperative planning of deep inferior epigastric artery perforator flaps.

Journal of plastic, reconstructive & aesthetic surgery : JPRAS·2008
Same author

Autologous fat transfer--a review of the literature with a focus on breast cancer surgery.

Journal of plastic, reconstructive & aesthetic surgery : JPRAS·2008

Area of Science:

  • Orthopedics
  • Biomedical Engineering
  • Rehabilitation Medicine

Background:

  • Accurate measurement of hand joint angles is crucial for diagnosing and monitoring conditions affecting hand function.
  • Existing methods for measuring metacarpophalangeal (MCP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joint angles can be time-consuming.
  • Standardized and efficient assessment tools are needed to improve clinical practice and patient care.

Purpose of the Study:

  • To introduce a novel goniometer designed for the simultaneous measurement of MCP, PIP, and DIP joint angles.
  • To enhance the efficiency and accuracy of recording patient hand joint mobility.
  • To provide a simplified method for documenting hand movements for clinical and research purposes.

Main Methods:

  • Development of a specialized goniometer capable of capturing multiple joint angles concurrently.
  • Testing the goniometer's ability to measure angles of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints.
  • Integration of a recording or tracing feature for visual documentation.

Main Results:

  • The goniometer enables simultaneous measurement of all three key hand joint angles.
  • The device significantly reduces the time required for hand joint angle assessment.
  • The system facilitates the creation of clear visual records of patient hand movements.

Conclusions:

  • This novel goniometer offers a faster and more streamlined approach to assessing hand joint mobility.
  • The tool simplifies the process of obtaining accurate and visual records of patient hand movements.
  • Implementation of this device can improve the efficiency of clinical evaluations and data collection in hand therapy and research.

Related Experiment Videos