[Exposure of recovery room personnel to inhalation anesthetics]
Related Experiment Video
Updated: Oct 24, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
K Westphal1, C Byhahn, U Strouhal
1Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Johann Wolfgang Goethe-Universität Frankfurt/Main.
Abstract:
Both desflurane and sevoflurane have a favourable blood/gas distribution coefficient. There is concern, however, that environmental contamination is higher when these agents are employed since they must be used in relatively high concentrations. Our study seeks to determine the degree of exposure of recovery room staff to trace amounts of these two agents. Two hundred and seven surgical patients were included in the study. The recovery room studied had a volume of 243 cubic metres. The hourly fresh air supply for this room was 1,845 cubic metres, which results in 7.6 air exchanges per hour without air return. Measurements of trace concentrations of the inhalational agents were taken for 12 days. Concentrations of these anaesthetics were assessed in the recovery room with a real-time infrared spectrometer every 90 seconds. Mean exposure to nitrous oxide in the recovery room was 11.5 +/- 3.97 ppm and to isoflurane 1.4 +/- 0.31 ppm. All measured values were below the standard German threshold values. Trace concentrations of desflurane were 2.8 +/- 0.84 ppm and of sevoflurane 3.2 +/- 0.62 ppm. We conclude that the exposure to the inhalational anaesthetics in the climatised recovery room was low. The threshold values of 100 ppm for nitrous oxide and 10 ppm for isoflurane recommended by German law were not exceeded. When the new volatile anaesthetics are used, exposure of recovery room staff to trace concentrations of these agents is higher, but the concentrations do not exceed the levels allowed applicable German health regulations.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Inhalational Anesthetics: Overview
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...