Related Experiment Video
Updated: Jul 21, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Direct morphological comparison of vacuum plasma sprayed and detonation gun sprayed hydroxyapatite coatings for
H C Gledhill1, I G Turner, C Doyle
1Department of Materials Science and Engineering, University of Bath, Claverton Down, UK.
Abstract:
Hydroxyapatite coatings on titanium substrates were produced using two thermal spray techniques vacuum plasma spraying and detonation gun spraying. X-ray diffraction was used to compare crystallinity and residual stresses in the coatings. Porosity was measured using optical microscopy in conjunction with an image analysis system. Scanning electron microscopy and surface roughness measurements were used to characterise the surface morphologies of the coatings. The vacuum plasma sprayed coatings were found to have a lower residual stress, a higher crystallinity and a higher level of porosity than the detonation gun coatings. It is concluded that consideration needs to be given to the significance of such variations within the clinical context.