Related Experiment Video
Updated: Aug 19, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Local cold exposure test with a new arterial photoplethysmographic sensor in healthy controls and patients with
1Dr. T. Schulz/Dr. M. Hahn Gemeinschaftspraxis für Dermatologie, Königstrasse 25, Rottweil, 78628, Germany.
Abstract:
Local cold exposure tests are used to diagnose cold-induced vasospastic disorders and to evaluate therapeutic success. We investigated the pulsatile signal detected with a newly developed arterial photoplethysmography (APPG) method and the signal change induced by local cold exposure using a temperature-controlled finger holder, comparing it with laser Doppler flux (red and green laser, rLDF and gLDF) and red blood cell velocity measured in nailfold capillaries (CBV). Ten healthy volunteers and 10 age- and sex-matched patients suffering from Raynaud's phenomenon due to systemic sclerosis were investigated using a moderate cooling temperature of 16 degrees C for 5 min. All signals were recorded simultaneously. The results show a significant reduction of CBV (P < 0.0001), rLDF (P < 0.0003), and gLDF (P = 0.0214) during cooling and characteristic changes in the APPG signal (for instance a decrease in pulse wave amplitude; P < 0.0001). Significant differences in the APPG amplitude could be detected under resting conditions; at cooling temperatures there were also significant differences in CBV and APPG. The temperature-controlled finger holder with its built-in APPG probe appears to be a useful tool for evaluating the effect of local cooling on finger skin perfusion and differentiating between healthy controls and patients with secondary Raynaud's phenomenon due to systemic sclerosis. The gLDF signal was rather weak, limiting its value in cold stress tests. The differences between controls and patients in CBV were somewhat smaller than in previous studies, suggesting the advantage of lower local cooling temperatures, e.g., 12 degrees C.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests