Related Experiment Video
Updated: Aug 14, 2026

Spinal Cord Lateral Hemisection and Asymmetric Behavioral Assessments in Adult Rats
Published on: March 24, 2020
Testing cerebrospinal fluid shunt capacity and adequacy by the lumbar route in adults
Abstract:
The pressure of the cerebrospinal fluid with the patient in a lateral position, the level of zero pressure in sitting position, and the infusion cisternography were evaluated as a test for determining shunt function. The lumbar infusion test gave information about shunt capacity, while the opening pressure in lateral and sitting position reflected shunt adequacy. A reduction in shunt capacity preceded the rise of the opening pressures when the shunt capacity preceded the rise of the opening pressures when the shunts became inadequate. Cisternography was relatively reliable in determining shunt adequacy when shunt capacity was near its high or low extreme, but unreliable in the middle ranges. In non-communicating hydrocephalus, the lumbar infusion test resulted in a correct conclusion as to shunt capacity provided the subarachnoid space was patent and the test was terminated before the ventricular system was empty.
More Related Videos
06:59Intrathecal Application of a Fluorescent Dye for the Identification of Cerebrospinal Fluid Leaks in Cochlear Malformation
Published on: February 29, 2020
14:59Neuronavigation and Laparoscopy Guided Ventriculoperitoneal Shunt Insertion for the Treatment of Hydrocephalus
Published on: October 14, 2022