Related Experiment Video
Updated: Aug 18, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Endotracheal tube narrowing after closed-system suctioning: prevalence and risk factors
C Glass1, M J Grap, C N Sessler
1Bon Secours, St Mary's Hospital, Richmond, Va., USA.
Background:
Few data exist about buildup of secretions within endotracheal tubes of patients treated with closed-system suctioning in the intensive care unit.
Objectives:
To describe the extent, prevalence, and distribution of narrowing of endotracheal tubes related to buildup of secretions and to determine contributing factors.
Methods:
Forty endotracheal tubes were examined within 4 hours of extubation, after at least 72 hours of use. Data on patients' daily weight and fluid balance, ventilator humidification temperatures, and nurses' descriptions of secretions during the 3 days preceding extubation were recorded. Any secretion debris in the endotracheal tubes was weighed. At 1-cm intervals along the tube, the debris was described and the depth of the debris was measured to the nearest 0.5 mm.
Results:
Mean duration of intubation was 6.6 days. Two tubes had no debris. Mean overall depth of debris was 0.64 mm, mean greatest depth was 2.0 mm (range, 0-5 mm), and mean weight was 1.16 g. The entire tube was affected, with the greatest depth of debris at the 6- to 9-cm and 13- to 14-cm markings. Duration of intubation correlated with mean greatest depth of debris (r = 0.37, P = .02), mean overall depth of debris (r = 0.48, P = .002), and mean weight of debris (r = 0.38, P = .02).
Conclusions:
Endotracheal tubes are markedly narrowed by the buildup of secretions after closed-system suctioning. Duration of intubation, but not endotracheal tube size or amount of secretions, was associated with the degree of narrowing.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy Suctioning II: Procedure