Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 10, 2014
Determination of scatter factor parameters and electron disequilibrium for monoenergetic photon beams
J McDonough1, P Bloch, B E Bjärngard
1Department of Radiation Oncology, University of Pennsylvania, Philadelphia 19104-4283, USA.
Abstract:
The tissue-phantom-ratio (TPR) is expressed as the product of the phantom scatter factor (SF), an electron disequilibrium factor, and an attenuation factor, equal to the zero-area TPR. The scatter factor, as a function of depth d and field size s, has been described by two parameters a and w, SF(d,s) = 1 + asd/(ws + d). We have determined the parameters a and w for 20 monoenergetic photon beams between 1 and 20 MeV. Pencil-beam energy-deposition kernels were obtained using Monte Carlo simulations. The kernels were used to calculate broad-beam depth-dose data, which were converted to TPR and fitted to the equation above using an iterative search over a-w space. The parameter a is nearly equal to the attenuation coefficient for all energies while the parameter w increases with energy. The resulting a and w compare favorably to values determined for clinical photon beams, as a function of the measured attenuation coefficient. With the scatter factor determined, we isolated the electron disequilibrium factor for each monoenergetic beam. It can be characterized as a quadratic function of the depth. The coefficients of the quadratic function can be related to the range of the most energetic secondary electron produced.
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...