Related Experiment Video
Updated: Jul 20, 2026

Physiology Lab Demonstration: Glomerular Filtration Rate in a Rat
Published on: July 26, 2015
Design of optimal two-sample bolus injection tests for measuring low plasma clearance rates
1Institute of Systems Science and Biomedical Engineering (LADSEB-CNR), Padova, Italy. karl@ladseb.pd.cnr.it
Abstract:
The bolus injection technique is widely used for assessing plasma clearance rates of substances and is based on multiexponential data analysis of multiple concentration measurements. This approach can be simplified to a monoexponential description with only two measurements if intercompartmental mixing occurs at a much faster rate than elimination, i.e. with low plasma clearance rates. In this context initial transients must be ignored because the first measurement time instant affects the accuracy of clearance estimates if mixing is still incomplete. Moreover, measurement noise affects estimation precision which can be optimized by suitable choice of the sampling schedule and of the injected test dose. The aim of this study is to design two-sample bolus injection tests for measuring low plasma clearance rates with preassigned precision and with minimum amount of injected test substance. This paper provides equations for evaluating whether plasma clearance is sufficiently low to allow a monoexponential description of the plasma disappearance curve and for choosing the first sampling time instant. Closed form equations are proposed for determining the optimal test dose and the second sampling time. Result are derived for a particular heteroscedastic measurement noise description, and the problem of robustness with respect to interpatient variability of kinetic parameters is addressed.
Related Concept Videos
Compartment Models: Two-Compartment Model
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...

