Related Experiment Video
Updated: Aug 18, 2026

12:19
Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
Published on: April 4, 2017
The supply module: recouping lost revenue
1Hinsdale Hospital, IL.
Abstract:
The authors describe how computerization helped to improve materiel management in the OR, including inventory control and purchasing, and how they acutally enabled them to recoup lost revenue.
More Related Videos
Related Concept Videos
Conservation of AC Power
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
Reducing Line Loss
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Carrier Generation and Recombination
Carrier generation is the process by which electron-hole pairs (EHPs) are created within the semiconductor. In direct-bandgap semiconductors, such as gallium arsenide (GaAs), this occurs efficiently when energy absorption prompts valence electrons to leap into the conduction band, leaving behind holes.
This process is given by the generation rate G and is efficient due to the conservation of momentum between the valence band maximum and conduction band minimum.
Indirect generation involves an...
This process is given by the generation rate G and is efficient due to the conservation of momentum between the valence band maximum and conduction band minimum.
Indirect generation involves an...
Power System Distribution
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
Fast Decoupled and DC Powerflow
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
Power System Three-Phase Short Circuits
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...

