Related Experiment Video
Updated: Aug 14, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices
Published on: October 3, 2016
Evaluation of the Plazlyte Sterilization System at the Richmond Hospital, Richmond, B.C
1Richmond Hospital, British Columbia.
Abstract:
Ethylene oxide mixed with chlorofluorocarbons has been the sterilant of choice for heat- and pressure-sensitive instruments and equipment in most Canadian and U.S. healthcare facilities. A pending July 1, 1994 ban on CFCs in British Columbia propelled the Greater Vancouver Regional Hospital District (GVRHD) to seek out any new available technologies to replace EtO sterilization. AbTox Plazlyte Sterilization System, which employs a proprietary, low-temperature gas plasma in conjunction with vaporized peracetic acid chemistry to provide terminal sterilization of instruments and devices, appeared very promising. A task force was formed at the Richmond Hospital to develop and implement a clinical isolate test protocol of the system. Following the three-month trial, the results showed the system to be effective in sterilizing all clinical isolates and compatible with the materials tested. There has also been improved product throughput. The Richmond Hospital now uses one Plazlyte sterilizer to process all items formerly processed using EtO.
More Related Videos
11:13Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...