Is oral endotracheal intubation efficacy impaired in the helicopter environment?
1University of Kentucky Medical Center, Lexington 40536.
Introduction:
Patients transported by helicopter often require advanced airway management. The purpose of this study was to determine whether or not the in-flight environment of air medical transport in a BO-105 helicopter impairs the ability of flight nurses to perform oral endotracheal intubation.
Setting:
The study was conducted in an MBB BO-105 helicopter.
Methods:
Flight nurses performed three manikin intubations in each of the two study environments: on an emergency department stretcher and in-flight in the BO-105 helicopter.
Results:
The mean time required for in-flight intubation (25.9 +/- 10.9 seconds) was significantly longer than the corresponding time (13.2 +/- 2.8 seconds) required for intubation in the control setting (ANOVA, F = 38.7, p < .001). All intubations performed in the control setting were placed correctly in the trachea; there were two (6.7%) esophageal intubations in the in-flight setting. The difference in appropriate endotracheal intubation between the two settings was not significant (chi 2 = 0.3; p > 0.05).
Conclusion:
Oral endotracheal intubation in the in-flight setting of the BO-105 helicopter takes approximately twice as long as intubation in a ground setting. The results support pre-flight intubation of patients who appear likely to require urgent intubation during air medical transport in the BO-105 helicopter.