Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Non-invasive assessment of human baroreflex during different body positions
R Iida1, K Hirayanagi, K Iwasaki
1Department of Anesthesiology, Surugadai Nihon University Hospital, Tokyo, Japan.
Abstract:
Two techniques for evaluating human baroreflex sensitivity (BRS), i.e. the sequence technique and the cross-spectral technique, were compared during the following four different body positions; 6 degrees head-down tilt (HDT), supine (Sup), 60 degrees head-up tilt (HUT) and upright (Upr). The sequence technique is based on the slope of linear regression between beat-to-beat RR intervals and systolic blood pressures. The cross-spectral technique is based on the cross-spectral analysis of RR interval and systolic blood pressure variabilities, and the estimates of BRS were computed separately for the low-frequency region (0.04-0.15 Hz) and the high-frequency region (0.15-0.5 Hz). The BRS obtained by the sequence technique had a significant correlation to that obtained by the cross-spectral technique for the low-frequency region in HDT, Sup and HUT, but not in Upr. There was a significant correlation between the BRS obtained by the sequence technique and that obtained by the cross-spectral technique for the high-frequency region in every body position. It became clear that the sequence technique is mutually related to the cross-spectral technique for the high-frequency region, but not necessarily identical to the cross-spectral technique for the low-frequency region. Moreover, a comparison was also made between the baroreceptor activating sequence and the deactivating sequence in the sequence technique during the four different body positions. Although the estimates of BRS of the activating sequence and the deactivating sequence were similar in every body position, the numbers of their sequences were progressively separated in the order of HDT, Sup, HUT and Upr. The numbers of the activating sequence and the deactivating sequence in the sequence technique were found to be separated in a sympathetically dominant condition.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...