Performance trade-offs in in situ chemostat NMR
Related Experiment Video
Updated: Oct 23, 2026

Spin Saturation Transfer Difference NMR (SSTD NMR): A New Tool to Obtain Kinetic Parameters of Chemical Exchange Processes
Published on: November 12, 2016
C D Castro1, A P Koretsky, M M Domach
1Central Research Division, Pfizer Inc., Groton, Connecticut 06340, USA.
Abstract:
Investigating cell cultures with NMR requires high cell densities to provide adequate signal-to-noise, or scans must be summed over long time periods and short-term events are lost. The mixing within a chemostat can be used to shorten the time required to acquire informative in situ NMR spectra from cell cultures. However, performance trade-offs can occur between net signal, spectral resolution, and oxygenation due to sampling volume, conductivity, gas bubble, and fluid flow effects. These trade-offs and the effect of different mixing regimes were theoretically analyzed to quantify how device design decisions impact performance. The results were found to concur with data from cell-free NMR experiments performed in 18 mS/cm conductivity medium. The results also guided the redesign of an NMR bioreactor in terms of relative radio frequency (rf) coil and sample dimensions and other factors. The design, which entails using chemostat mixing to shunt sample through a rf coil in ca. 0.4 s, provides adequate oxygenation for the 4-16% (v/v) cell suspensions examined. Gains realized include lower conductive losses, better magnetic field homogeneity, and the exclusion of gas bubbles from the sampling zone. These gains enable the acquistion of spectra from dilute (3-4% v/v) Saccharomyces cerevisiae chemostat cultures in 6.9 min with high resolution in both the orthophosphate and the beta-NTP regions. Samples with 16% (v/v) cells also yield useful spectra within 0.5-1.0 min.
Related Concept Videos
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Nuclear Overhauser Enhancement (NOE)

