Related Experiment Video
Updated: Aug 13, 2026

Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse (POP) Quantification System
Published on: September 20, 2018
Pelvic floor descent in females: comparative study of colpocystodefecography and dynamic fast MR imaging
D Vanbeckevoort1, L Van Hoe, R Oyen
1Department of Radiology, University Hospitals, Leuven, Belgium.
The purpose of this study was to compare fast dynamic magnetic resonance imaging (MRI) with colpocystodefecography (CCD) in the evaluation of pelvic floor descent in women. Thirty-five women with clinical evidence of pelvic floor descent were studied. A fast single-shot MR sequence was performed in the supine position during pelvic floor relaxation and during maximal pelvic strain. On the same day, a dynamic CCD was performed with the patient seated on a stool-chair. The degree of descent of the bladder, vagina, and anorectal junction was evaluated as the vertical distance between the pubococcygeal line and the bladder base, the vaginal vault, and the anorectal junction, respectively. A bulge of more than 3 cm measured as the distance between the extended line of the anterior border of the anal canal and the tip of the rectocele was interpreted as a rectocele. MRI was compared with CCD during maximal pelvic strain (CCD 1) and during voiding and defecation (CCD II). CCD was considered as the gold standard. Compared with clinical examination, CCD I showed a larger number of involved compartments, except for the middle compartment. CCD II was superior to clinical examination in all cases. In comparison with CCD I and especially CCD II, MRI had a lower sensitivity, especially for the anterior and middle compartment. Even four enteroceles seen on CCD II were not detected by MRI. When CCD I and CCD II were compared, a cystocele, a vaginal vault prolapse, an enterocele, and a rectocele were more readily seen on CCD II than with CCD I. When compared with CCD, supine dynamic MRI is unreliable, especially in the anterior and middle compartment. Even in the detection of enteroceles CCD was superior to MRI. In general, the best results with MRI can be expected for evaluation of the rectum.
The purpose of this study was to compare fast dynamic magnetic resonance imaging (MRI) with colpocystodefecography (CCD) in the evaluation of pelvic floor descent in women. Thirty-five women with clinical evidence of pelvic floor descent were studied. A fast single-shot MR sequence was performed in the supine position during pelvic floor relaxation and during maximal pelvic strain. On the same day, a dynamic CCD was performed with the patient seated on a stool-chair. The degree of descent of the bladder, vagina, and anorectal junction was evaluated as the vertical distance between the pubococcygeal line and the bladder base, the vaginal vault, and the anorectal junction, respectively. A bulge of more than 3 cm measured as the distance between the extended line of the anterior border of the anal canal and the tip of the rectocele was interpreted as a rectocele. MRI was compared with CCD during maximal pelvic strain (CCD 1) and during voiding and defecation (CCD II). CCD was considered as the gold standard. Compared with clinical examination, CCD I showed a larger number of involved compartments, except for the middle compartment. CCD II was superior to clinical examination in all cases. In comparison with CCD I and especially CCD II, MRI had a lower sensitivity, especially for the anterior and middle compartment. Even four enteroceles seen on CCD II were not detected by MRI. When CCD I and CCD II were compared, a cystocele, a vaginal vault prolapse, an enterocele, and a rectocele were more readily seen on CCD II than with CCD I. When compared with CCD, supine dynamic MRI is unreliable, especially in the anterior and middle compartment. Even in the detection of enteroceles CCD was superior to MRI. In general, the best results with MRI can be expected for evaluation of the rectum.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies II: Ultrasonography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Urodynamic Studies: Uroflowmetry

