Objective:
This study was undertaken to test the hypothesis that hemodialysis with a large-pore membrane would improve heart function during acute endotoxin shock.
Setting:
Large animal laboratory.
Design:
Eighteen mongrel dogs were instrumented to measure left ventricular maximum end-systolic elastance (left ventricular maximum elastance at end systole), cardiac output, circumflex artery blood flow, and myocardial mechanical efficiency (CO x MAP/MVO2, where CO is cardiac output, MAP is mean arterial pressure, and MVO2 is myocardial oxygen consumption). Plasma catecholamine concentrations were determined by high-performance liquid chromatography. Endotoxin shock was induced by infusing 5.0 microg/kg/min of Escherichia col 0127:B8 endotoxin in the portal vein for 60 mins, followed by 2.0 microg/kg/min of constant infusion. Control dogs (n = 6) received 4.0 mL/kg/min of saline; hemodialysis dogs (n = 6) underwent venovenous hemodialysis in 50-min intervals using a polysulfone filter (1.2 m2; mean pore size, 0.50 nm; blood flow rate, 400 mL/min; ultrafiltrate, "zero-balanced"); shams (n = 5) were treated identically to hemodialysis dogs, except that no convective dialysis was performed. A fourth group (n = 6) was treated with dopamine (5.0-7.0 microg/kg/min, optimal dose for contractile increase based on dose-response studies).
Measurements And Main Results:
After 2 hrs of treatment, left ventricular maximum elastance at end systole increased and was unchanged in controls (30 +/- 5 mm Hg/mm) and shams (24 +/- 6 mm Hg/mm) compared with basal control. Hemodialysis treatment increased contractility (53 +/- 4 mm Hg/mm), as did dopamine treatment (54 +/- 7 mm Hg/mm). Endotoxin shock reduced mechanical efficiency to 45% of basal control; with hemodialysis treatment, left ventricular efficiency returned to 64% of basal control measurement, compared with 49% with dopamine treatment. During treatment, myocardial glucose uptake was increased with hemodialysis compared with other groups. No difference was observed among groups for left ventricular end-diastolic pressures or dimensions, or catecholamine concentrations.
Conclusions:
Large-pore hemodialysis increased left ventricular contractility to a similar degree as dopamine and provided a marginal improvement in myocardial glucose uptake and mechanical efficiency.