W A Budris1, D M Roxe, J M Duvel
1Department of Pharmacy, Northwestern Memorial Hospital, Chicago, IL 60611, USA.
Objective:
To report a case of high anion gap metabolic acidosis related to infusion of aminocaproic acid (ACA) that temporarily corrected during hemodialysis and resolved upon ACA discontinuation.
Case Summary:
A 65-year-old white woman with staphylococcal sepsis complicated by acute renal failure was treated with ACA to control a hemorrhagic coagulopathy. After receiving an initial 5-g bolus of ACA, she received a continuous intravenous infusion of 500 mg/h for just over 5 days, then 250 mg/h for a final 12 hours. Immediately after beginning ACA therapy, she developed a severe anion gap metabolic acidosis that briefly improved after hemodialysis. The condition resolved completely only after the discontinuation of ACA and therapy with a systemic alkalinizer.
Discussion:
ACA is not among the previously identified causes of high anion gap metabolic acidosis. The temporal profile relating anion gap to ACA initiation, hemodialysis treatment, and ACA discontinuation supports causality in this case. The magnitude of increase in the anion gap appears to have been proportional to the dose of ACA.
Conclusions:
In patients with renal impairment, ACA administration may produce a dose-related, high anion gap metabolic acidosis that might be reversible during hemodialysis. Insufficient data are available, but when ACA must be used in such patients, a more conservative dosing of ACA should be coupled with close monitoring.
Related Concept Videos
Acid-Base Balance
When the pH of arterial blood rises above 7.45, it results in a condition called alkalosis. Conversely, a drop below 7.35 leads to...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Acute Respiratory Failure-III
Diabetic Ketoacidosis l: Introduction
Diabetic Ketoacidosis ll: Pathophysiology