Related Experiment Video
Updated: Jul 23, 2026

06:10
Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Effectiveness of the A-V impulse hand pump.
M Ramesh1, B Morrissey, J B Healy
1Sligo General Hospital, Ireland.
The Journal of Bone and Joint Surgery. British Volume
|April 16, 1999
Summary
A pneumatic compression device effectively reduced acute hand swelling and pain, improving function after trauma or surgery. This innovative hand pump offers a significant reduction in swelling, leading to faster recovery and near-normal hand function upon hospital discharge.
Area of Science:
- Orthopedics
- Vascular Surgery
- Rehabilitation Medicine
Background:
- Acute hand swelling is a frequent complication post-trauma or surgery.
- Swelling leads to significant pain and functional deficits.
- Effective management strategies for hand edema are crucial.
Purpose of the Study:
- To evaluate the efficacy of a pneumatic compression device (A-V impulse hand pump) in managing acute hand swelling.
- To assess the impact of the device on venous return, pain, and hand function.
- To determine optimal usage protocols for the pneumatic hand pump.
Main Methods:
- Prospective study involving 47 patients with acute hand swelling.
- Utilized a pneumatic compression device (A-V impulse hand pump).
- Assessed swelling reduction, venous return velocity (Duplex scan of median cubital vein), pain levels, and hand function.
Main Results:
- Continuous 48-hour use reduced swelling by 78.6% compared to the uninjured hand.
- Intermittent use (12 hours/24 hours) also showed statistically significant swelling reduction.
- Reported subjective pain reduction and objective functional improvement.
- Patients achieved near-normal hand function by hospital discharge (average 48 hours).
Conclusions:
- The A-V impulse hand pump is an effective treatment for acute hand swelling.
- The device enhances venous return, alleviates pain, and restores hand function.
- Pneumatic compression offers a promising therapeutic option for post-traumatic and post-surgical hand edema.
Related Concept Videos
ATP Driven Pumps II: P-type Pumps
The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
ATP Driven Pumps III: V-type Pumps
V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Pulse
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...