Related Experiment Video
Updated: Aug 19, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Mammography in the 1990s: the United States and Canada
O H Suleiman1, D C Spelic, J L McCrohan
1U.S. Food and Drug Administration, Center for Devices of Radiological Health, Rockville, MD 20850, USA.
Purpose:
To evaluate trends in mammography quality before and after the implementation of the Mammography Quality Standards Act (MQSA) of 1992 and to compare technical data collected in the United States with corresponding data obtained from the first survey of mammography facilities conducted in 1994-1995 in Canada.
Materials And Methods:
Data from MQSA inspections conducted in 1995-1997 were analyzed and compared with survey data on U.S. mammography facilities acquired before the MQSA. Technical indicators of mammography quality such as radiation dose phantom image score, film processing, and darkroom fog were analyzed.
Results:
In the United States, phantom image scores, along with other technical measures of performance such as film processing, darkroom fog, and x-ray beam quality, have improved continuously since 1985. The U.S. mean glandular dose has increased to 1.6 mGy compared with the Canadian dose of 1.1 mGy. The mean total phantom image score with artifact subtraction was 11.1 in Canada in 1994-1995 and 11.8 in the U.S. in 1997.
Conclusion:
Mammography quality is better today than it has been at any other time in the United States. With the exception of radiation dose. Canadian technical measures of performance are comparable to measures before MQSA in the United States.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging