Related Experiment Video
Updated: Aug 12, 2026

Repeated Orotracheal Intubation in Mice
Published on: March 27, 2020
Significant tracheal obstruction causing failure to wean in patients requiring prolonged mechanical ventilation: a
M J Rumbak1, F W Walsh, W M Anderson
1Department of Medicine, University of South Florida College of Medicine Health Science Center, Tampa, USA. DMRUMCAKE@AOL.com
Introduction:
Modern low-pressure, high-volume cuffed tracheotomy tubes have been shown to decrease tracheal injury. However, injury still occurs in patients requiring prolonged mechanical ventilation and prevents weaning, delays decannulation, prolongs hospitalization, and may totally obstruct the airway. We describe 37 patients, including the first reported case of failure to wean due to tracheal obstruction.
Methods:
Over a 3-year period, from September 1994 to August 1997, the hospital records of 37 patients requiring prolonged mechanical ventilation (> 4 weeks) and found to have tracheal obstruction were reviewed retrospectively. They were a subgroup of 756 patients admitted to hospitals during the same period. The average endotracheal/tracheostomy cannulation time was 3 weeks/12 weeks (range 2 to 4 weeks/8 to 14 weeks). Average age was 76 years (range, 34 to 81). Underlying diseases included COPD, postcoronary artery bypass graft surgery, postpneumonectomy, severe pneumonia, acute lung injury, and ischemic heart disease.
Results:
All 37 patients who initially failed to wean had difficulty in breathing and developed intermittent high peak airway pressures either early or during the weaning process or just on being ventilated. The insertion of a longer tracheal tube bypassed the obstruction, reestablished the airway, decreased peak airway pressures, and allowed the patient to breathe more easily. The obstruction was confirmed on bronchoscopy. Treatment consisted of either placement of a longer tracheal tube (34 of 37 patients) or placement of a tracheal stent. All but two of the patients (5.4%) were able to be weaned within a week. The two patients who still failed to be weaned were subsequently diagnosed as having amyotrophic lateral sclerosis.
Conclusion:
Tracheal obstruction in patients requiring prolonged mechanical ventilation prevented weaning. Reestablishment of the airway with a longer tracheal tube or tracheal stent allowed most of the patients to be weaned.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.