Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Determination of trace level gamma-aminobutyric acid using an improved OPA pre-column derivatization and on-column
1Department of Chemistry, University of Florida, Gainesville 32611-7200, USA.
Abstract:
An improved pre-column derivatization with o-phthalaldehyde/tert-butylthiol and on-column preconcentration are used with packed capillary liquid chromatography and electrochemical detection to obtain low concentration detection limits for gamma-aminobutyric acid (GABA). Using derivatization procedures from the literature, it was found that the detection limits for GABA were 380 amol in 50 microns i.d. packed capillaries, which is over 10-fold worse than the detection limit possible with the instrumentation. The higher detection limit was directly the result of electroactive interferences generated by the derivatization chemistry. Derivatization was improved by scavenging excess reagents with excess amine and iodoacetamide. With these improvements, the interfering peaks were eliminated and the detection limit was improved to 50 amol. With injection volumes of 0.5 microL, under conditions that permitted on-column preconcentration, the concentration detection limit, that is the concentration at which analytes could be derivatized and detected, was 100 pM. The technique was applied to determination of GABA release from islets of Langerhans.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...