Should one use electrocardiographic or Finapres-derived pulse intervals for calculation of cardiac baroreceptor
1University Department of Medicine for the Elderly, The Glenfield Hospital, Leicester, UK.
Abstract:
BACKGROUND: Cardiac baroreceptor sensitivity (BRS) can now be calculated non-invasively with the advent of new beat-to-beat blood pressure monitors and simulatneous surface electrocardiographic recording. However, it is not known whether BRS values calculated using a pulse interval obtained from the pulse wave are different from those using the electrocardiographic trace. This is important with the advent of new portable monitors (e.g. Portapres), which do not record a simultaneous electrocardiographic trace. OBJECTIVE: To determine whether pulse interval derivations from pulse wave data and electrocardiographic data are comparable.METHODS: Twenty healthy volunteers (10 men) aged 48 +/- 17 years with mean blood pressure 134 +/- 13/77 +/- 7 mmHg were examined. Supine beat-to-beat arterial blood pressure (measured using a Finapres 2300 device from Ohmeda) and surface electrocardiographic readings were recorded and spectral analysis, using fast Fourier transformation (FFT), and sequence analysis used to calculate BRS. Pulse interval was marked using both electrocardiographic and blood pressure traces and we compared the resulting variability of pulse interval and BRS values obtained using the two methodologies. RESULTS: There was good agreement between the two methods for pulse interval power in the low-frequency bandwidth and for BRS sequence analysis, especially for 'down' sequences, (limits of agreement -26.3 to 77.1 ms2 and -1.6 to 2.7 ms/mmHg, respectively). However, in the high frequency bandwidth (0.15-0.35 Hz) and for the combined BRS, the agreement was less good (-69 to 153.8 ms2 and -0.3 to 1.5 ms/mmHg). Overall differences between methods were smaller for BRS calculated in the low frequency rather than high-frequency band, but only in the low-frequency band was the difference positively correlated to mean BRS values. CONCLUSION: Cardiac BRS values calculated using pulse intervals derived from the pulse wave are different from those on the surface electrocardiographic trace, the greatest differences occurring in BRS derived from the high-frequency bandwidth. However, these differences are small, especially in the low-frequency band at lower mean BRS values, and should not discourage use of these newer methods of BRS measurement that do not involve an electrocardiographic recording.
More Related Videos
Related Concept Videos
Special considerations while measuring pulse
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse
The pulse serves as a clinical indicator...