Telemedical evaluation of ocular adnexa and anterior segment
A B Threlkeld1, T Fahd, M Camp
1Glaucoma Service, Medical College of Georgia, Augusta, USA.
Purpose:
To report the accuracy of telemedical slit-lamp evaluation in examination of ocular adnexa and anterior segment.
Methods:
By means of contingency tables, slit-lamp findings by live examination and by real-time telemedicine were compared in 50 eyes of 25 patients.
Results:
Sensitivity percentages (proportion with findings correctly identified by telemedicine)/specificity percentages (proportion without the finding that was correctly identified by telemedicine) were 100/64 for eyelid mass, 100/85 for conjunctival pigment, 100/100 for posterior synechiae, 80/0 for blepharitis, 83/93 for iridotomy, 70/93 for pinguecula, 75/93 for iris lesions, 56/98 for corneal scar, 0/100 for chamber inflammation, 57/93 for nuclear cataract, and 37/100 for intraocular lens presence.
Conclusions:
By means of monocular slit-lamp telemedical evaluation, clinical findings with high contrast cues for color and depth have the highest sensitivity and specificity.