Non-invasive assessment of ocular pharmacokinetics using Confocal Raman Spectroscopy
N J Bauer1, M Motamedi, J P Wicksted
1Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston, USA.
Abstract:
A Laser Scanning Confocal Raman Spectroscopy (LSCRS) system was applied for the non-invasive quantification of the transport of a drug through the rabbit cornea in vivo. Employing LSCRS, the changes in the amplitude of a drug-specific Raman signal were assessed over time in the tearfilm and corneal epithelium of the living rabbit eye (n = 6), after topical application of 25 microL Trusopt 2%. This allowed for quantification of pharmacokinetic variables. The effect of the drug on corneal hydration was also monitored. LSCRS demonstrated adequate sensitivity and reproducibility, for continuous real-time monitoring of the Trusopt concentration. Each concentration-time curve had a bi-phasic trend; the rapid initial phase (t<8 min.) corresponds to the nonproductive losses of Trusopt from the tears (k10 = 0.24+/-0.04 min(-1), and the slower later phase (t>20 min.) is the result of transfer of the drug from the corneal epithelium to the stroma (k23 = 0.0047+/-0.0004 min(-1). Drug absorption into the corneal epithelium occurred at a rate of k12 = 0.034+/-0.006 min(-1). Trusopt caused an acute dehydrating effect, with a maximum decrease in corneal hydration of approximately 15% at approximately 60 min. following application of the drug. LSCRS has the specificity, sensitivity, reproducibility and spatial resolution for employment as a potentially valuable tool for the study of ocular pharmacokinetics.
More Related Videos
09:32Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
07:12Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
Published on: September 27, 2021
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...