A heat recovery system for air conditioning which allows disposal of wet cooling towers
Abstract:
The combined run-around coil heat recovery and cooling plant has been in full operation for about four months at the time of writing and appears to be performing as predicted. The predicted energy saving was 19,000 GJ/year and the actual is around 18,000 GJ/year. It provides a general limited cooling facility of 6 degrees K where previously cooling existed for operating theatres only. The capital cost of the total project was 390,000 pounds and disregarding fuel price fluctuations the heat recovery scheme should pay for itself in about seven years. In addition to the heat recovery and cooling provisions offered the scheme also enabled correction of a frost protection problem plus disposal of an existing wet cooling tower and hence should reduce the risk of Legionnaires Disease. Had these two projects been implemented separately the cost would have been 80,000 pounds but without heat recovery. The advantages of the scheme may be summarised as follows. Energy Cost Savings Frost Protection Elimination of Wet Cooling Tower Cooling Facility It is believed that a scheme as described in this paper would be of benefit to other existing hospitals and should be considered at the design stage of future new hospitals. At IRH it was possible to dispense completely with a wet cooling tower; for other schemes this may also be possible or at least the size and capacity of cooling towers could be reduced.
More Related Videos
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from the...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mechanism of heat transfer
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...
Biological Treatment of Effluent and Waste Water
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...