Shunt control of bleeding after homograft replacement of the ascending aorta

M C Mancini1, E M Cush

  • 1Department of Surgery, Louisiana State University Medical Center, Shreveport 71130, USA. mmanci@lsumc.edu

Homograft replacement of the ascending aorta with replacement of the coronary arteries often is accompanied by significant postoperative bleeding from the suture lines that often requires a second exploratory operation. These events occur despite a meticulous operative technique and pharmacologic hemostatic agents. We used hemostatic material to cover the homograft as patch to create a watertight seal and placed a left-to-right shunt to control bleeding.