Morphological evaluation of a regurgitant orifice by 3-D echocardiography: applications in the quantification of
A S Anayiotos1, B K Smith, M Kolda
1School of Engineering, University of Alabama at Birmingham, 35294-4460, USA. aanayiot@eng.uab.edu
Insights
Accurately assessing heart valve regurgitation is challenging. This study introduces a novel method using 3-D echocardiography and Doppler velocimetry for precise blood flow calculation, improving clinical evaluation.
Area of Science:
- Cardiovascular Imaging
- Medical Engineering
- Hemodynamics
Background:
- Clinical evaluation of blood flow regurgitation through heart valves remains a significant challenge.
- Existing methods lack accuracy due to insufficient geometric information of the regurgitant orifice.
Purpose of the Study:
- To develop and validate a superior method for calculating regurgitant variables using 3-D echocardiography and Doppler velocimetry.
- To address the limitations in assessing heart valve function and stenosis.
Main Methods:
- Utilized three-dimensional (3-D) echocardiography to construct the geometric structure of a regurgitating porcine prosthetic valve orifice.
- Employed color Doppler flow mapping (CD) and continuous-wave Doppler (CW) to assess the velocity flowfield.
- Developed two calculation methods: peak regurgitant flow rate from CD and regurgitant flow volume from CW.
Main Results:
- Both developed calculation methods demonstrated excellent correlation with true values obtained from an electromagnetic flowmeter.
- The 3-D echocardiography approach successfully provided detailed geometric information of the valve orifice.
- Preliminary results in a realistic porcine model showed high accuracy.
Conclusions:
- The combined use of 3-D echocardiography and Doppler velocimetry offers a superior and accurate method for calculating regurgitant variables.
- This technique holds promise for establishing a routine clinical procedure for evaluating heart valve regurgitation and stenosis.
- Further clinical testing is warranted to validate these findings in human patients.
Abstract:
The clinical evaluation of blood flow regurgitation through a heart valve or stenotic lesion is an unresolved problem. The proximal flowfield region has been the study focus in the last few years; however, investigators have failed to identify an accurate and reliable calculation scheme due to lack of geometric information about the shape and size of the regurgitating or stenotic orifice. Presented here is a superior method of calculation, by using three-dimensional (3-D) echocardiography combined with Doppler velocimetry. The geometric structure of the orifice in a regurgitating porcine prosthetic valve in vitro was formulated by 3-D image construction of sequentially obtained 2-D images. The velocity flowfield was accessed by color Doppler flow mapping (CD) and continuous-wave Doppler (CW). Two accurate methods of calculation of regurgitant variables were developed. The first method calculated peak regurgitant flow rate from CD and the second method calculated regurgitant flow volume from CW. Both methods showed excellent correlation with the corresponding true values from an electromagnetic flowmeter. The promising preliminary results in such a realistic porcine model indicate the possibility of establishing a routine procedure to be tested in the clinical setting.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Mitral Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management