Systematic errors in estimating mean blood pressure from finger blood pressure measurements
Related Experiment Video
Updated: Oct 20, 2026

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
C J O'Callaghan1, N E Straznicky, K Komersova
1Department of Medicine, University of Melbourne, Austin and Repatriation Medical Centre, Heidelberg, Australia. cjo1@le.ac.uk
Abstract:
The mean blood pressure (BP) can be accurately estimated from indirect measurements of brachial artery pressure, i.e. mean BP = diastolic BP + 1/3 pulse pressure. Although this equation has been used as a surrogate of mean systemic pressure, it is unknown whether this approximation can be validly applied to distal vascular beds. Therefore we determined the accuracy of this method as an estimate of the mean pressure in distal arteries by measuring finger BP with the Finapres device in 16 normotensive and 12 hypertensive subjects. The "calculated" and measured values of mean BP were compared when subjects were resting and during manoeuvres which aimed to alter the shape of the pulse waveform. Although closely correlated with the measured value, the "calculated" resting mean BP was systematically greater (+2.7+/-0.7 mm Hg, p<0.001). Additionally, the rise in the mean pressure produced by infusion of phenylephrine, an alpha1-adrenoceptor stimulant (16.0+/-1.5 mm Hg) was underestimated by the calculation (13.1+/-1.5 mm Hg, p<0.05). Of even greater concern was that calculating the mean pressure during infusion of isoprenaline (a beta-adrenergic stimulant) suggested the mean pressure had increased by 5.8+/-1.6 mm Hg when it had actually fallen (-2.1+/-2.4 mm Hg, p<0.001 vs. the measured value). Thus, calculating the mean BP from Finapres measurements roughly approximates the measured value when subjects are at rest. However, this estimation becomes inaccurate when pulse wave dimensions are altered, and is probably unsuitable for assessing the acute effects of vasoactive drugs, in particular vasodilators, on BP.
More Related Videos
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Random and Systematic Errors