Related Experiment Video
Updated: Aug 15, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
2D-finite element analyses and histomorphology of lag screws with and without a biconcave washer
P Schuller-Götzburg1, C Krenkel, T J Reiter
1Department of Oral- and Maxillofacial Surgery, Histological-Embryological Institute, University of Vienna, LKA-Salzburg, Austria.
Abstract:
For osteosynthesis and for bone transplant fixation in particular, a lag screw with a biconcave washer, the so called "Anchor Screw" (AS) has been introduced in maxillo-facial surgery. Using 2D-finite element analysis (FEA), the v. Mises and the circumferential stresses induced in underlying bone by this AS are analysed and compared to those under a conventional lag screw. The stress distributions below the biconcave washer of the AS were correlated with histomorphological bone reactions after AS osteosynthesis in two tumor patients, retrieved 12 weeks and 19 months after tumor surgery, respectively. Depending on the thickness of cortical bone, the v. Mises stress concentrations below the biconcave washer were lower than under the head of the conventional lag screw (CLS), but with a higher stress maximum concentrated around the rim of the washer. The circumferential stresses were only half as high around the AS, and thus the deformation of bone was reduced. As predicted by FEA, histology showed microcrack formation, but then after minimal resorption, remodelling of bone below the biconcave washer. Stable osteosynthesis could be demonstrated by bony union already after 12 weeks, and, while bone remodelling continued in the healed osteotomy, it had decreased around the screws after 19 months. It can be concluded from the biomechanical principles and the histomorphological findings that the AS appears superior to the CLS.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Thin-Walled Hollow Shafts
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Eccentric Axial Loading in a Plane of Symmetry