In vitro cytotoxicity and in vivo biocompatibility of poly(propylene fumarate-co-ethylene glycol) hydrogels
Related Experiment Video
Updated: Aug 2, 2026

Generation and Recovery of β-cell Spheroids From Step-growth PEG-peptide Hydrogels
Published on: December 6, 2012
L J Suggs1, M S Shive, C A Garcia
1Institute of Biosciences and Bioengineering and Department of Chemical Engineering, Rice University, Houston, Texas 77251-1892, USA.
Abstract:
The in vitro cytotoxicity and in vivo biocompatibility of poly(propylene fumarate-co-ethylene glycol) [P(PF-co-EG)] hydrogels were assessed in order to investigate the influence of poly(ethylene glycol) molecular weight and copolymer composition. These materials have application as injectable cardiovascular implants; cytotoxicity due to leachable products, as well as inflammation caused by the biomaterial itself, may ultimately affect the biocompatibility of the implant. We utilized a 7-day in vitro cytotoxicity assay to quantify cell density and cellular proliferation in the presence of copolymer films. The copolymer films exhibited slight to moderate cytotoxicity toward cultured endothelial cells, showing 20-86% viability relative to controls. Cell viability increased with an increasing weight percent of PEG or, to a lesser extent, the molecular weight of PEG. In vivo biocompatibility was assessed using a cage implantation model over a 21-day time period. This system was used to characterize the local cellular and humoral inflammatory response in the surrounding exudate, as well as the size and density of macrophages adherent to the material itself. All copolymer formulations exhibited excellent biocompatibility relative to controls with no significant differences in total leukocyte count among the different formulations. The in vivo inflammatory reaction displayed normal wound healing over 21 days as shown by a progressive decrease in both leukocyte concentration and enzymatic activity. The surface coverage of the copolymer films remained relatively constant from 7 to 21 days. There were no cells larger than 0.003 mm2, which was previously shown to be the threshold value for foreign-body giant cells. These data suggest that P(PF-co-EG) hydrogels have potential for use as injectable biomaterials.
More Related Videos
15:33Microwave-assisted Functionalization of Poly(ethylene glycol) and On-resin Peptides for Use in Chain Polymerizations and Hydrogel Formation
Published on: October 29, 2013
11:32Characteristics of Precipitation-formed Polyethylene Glycol Microgels Are Controlled by Molecular Weight of Reactants
Published on: December 23, 2013