Diode-Laser Measurements of He-, Ar-, and N2-Broadened HF Lineshapes in the First Overtone Band
1Department of Mechanical Engineering, Stanford University, Stanford, California, 94305-3032
Abstract:
High-resolution lineshapes of the HF P(3) and P(6) transitions (2-0 band) have been recorded in a 14.9-cm long absorption cell (T = 296 K) using a pair of (InGaAsP)-distributed feedback diode lasers operating near 1.31 and 1.34 µm, respectively. The absorption lineshapes were least-squares fit to Voigt, Rautian, and Galatry profiles to determine the collision widths and velocity-changing collision frequencies for the perturbers He, Ar, and N2. Motional narrowing was observed for the He-broadened lineshapes over a range of total pressures from 50 to 646 Torr. The Ar- and N2-broadened spectra showed a strong narrowing effect for pressures less than 400 Torr. At higher pressures, narrowing parameters could not be reliably determined due to the relatively large Ar- and N2-pressure broadening. The collision widths inferred from Voigt-profile fits were systematically less than those determined from Rautian and Galatry fits (up to 25% for the He-broadened P(6) transition). The measured pressure-induced broadening and shift coefficients were compared with other experimental data and full-quantal close-coupling (CC) scattering cross-section calculations. The measured Ar-broadening half-widths were in excellent agreement with calculated values, while the measured shifts were 10 and 20% less than calculated values for the P(3) and P(6) transitions, respectively. The measured N2-broadening and shift coefficients agree reasonably well with values determined from previous experiments. Copyright 1999 Academic Press.
Related Concept Videos
Emission Spectra
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
IR Frequency Region: X–H Stretching