Related Experiment Video
Updated: Oct 20, 2026

Hypercapnic Hyperventilation to Accelerate Emergence from Inhaled Volatile Anesthetics: A Practical Method Using Standard Hospital Equipment
Published on: June 26, 2026
Prolonged partial liquid ventilation in spontaneously breathing awake animals
P B Rich1, C A Reickert, S A Mahler
1Department of Surgery, The University of Michigan Hospitals, Ann Arbor, USA.
Objective:
To date, studies of partial liquid ventilation (PLV) have examined its effects acutely in anesthetized and mechanically ventilated subjects. We set out to develop a model of prolonged PLV in awake, spontaneously breathing animals.
Design:
Animal case series
Setting:
Cardiopulmonary physiology laboratory.
Subjects:
Fifteen New Zealand white rabbits (3.2+/-0.39 kg).
Interventions:
Animals were anesthetized and instrumented with a novel technique allowing percutaneously assisted placement of an intratracheal catheter with a subcutaneously tunneled externalized free end. After anesthetic recovery, PLV was performed in spontaneously breathing unsedated animals.
Measurements And Main Results:
Evaporative losses were determined using a single 10 mL/kg perflubron dose (n = 5); hourly radiographs were obtained until residual perflubron was minimal. For prolonged PLV (n = 10), a 10-mL/kg initial perflubron dose was followed every 4 hrs with 5-mL/kg supplements. Radiographs were obtained immediately before and after perflubron administration and were scored (0-5) by a radiologist blinded to dosing regimen and time interval. Data were analyzed with ANOVA and Student's t-test with correction for multiple comparisons. Initial filling was nearly complete (score = 4.8+/-0.42); lungs were maintained approximately half-filled through 4 hrs (score = 2.53+/-0.71). By 6 hrs, the majority of perflubron had evaporated (score = 1.75+/-0.53). Over 24 hrs, radiographs documented continuous perflubron exposure (postffill = 4.53+/-0.64, prefill = 3.40+/-0.71, average = 3.97+/-0.43); scores were comparatively higher after filling (after = 4.53+/-0.64, before = 3.4+/-0.71, p< .001). Left and right lung volumes were equivalent (left = 4.06+/-0.47, right = 3.89+/-0.39, p = .027). All animals survived the 24 hrs of PLV.
Conclusions:
Percutaneously assisted intratracheal cannulation with catheter exteriorization permits prolonged PLV in spontaneously breathing, unsedated animals. Continuous perfluorocarbon exposure with this method is reproducible, consistent, and well tolerated for 24 hrs in uninjured animals.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019