Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent
B Friberg1, S Friberg, L G Burman
1Department of Nursing, Northern University Hospital, Umea, Sweden.
Abstract:
Airborne contamination with bacteria-carrying particles (cfu/m3) and their sedimentation rate (cfu/m2/h) was compared in an operating room (OR) equipped with two turbulent ventilation systems. One was a thermally based system with inlet of cool clean air at the floor level and evacuation of the air at the ceiling by convection (17 air changes/h). The other was a conventional plenum pressure system with air supply at the ceiling and evacuation at the floor level (16 air changes/h). The study was made during rigidly standardised sham operations (N = 20) performed in the same OR by the same six member team wearing non-woven disposable or cotton clothing. Airborne contamination in the wound and instrument areas was related to the surface contamination rate in the same areas and in addition, on the patient chest and in the periphery of the OR. With the exception of the periphery of the OR, the surface and air contamination rates were highly correlated in both ventilation systems (P = 0.02-0.0006, r2 = 0.52-0.79). This was also true particularly when disposable clothing was used while the correlation was weaker in cotton clothing experiments. An equation describing the relation between surface and air counts is given. Typically, the surface counts were numerically 16-fold the air counts, i.e., the number of colonies sedimenting on four 14 cm-diameter agar plates during 1 h will almost equal the number of airborne cfu per m3. We propose, that sedimentation plates represent not only a technically easier method than air sampling but when correctly used, are also the most realistic indicator of airborne bacterial OR contamination in areas critical for surgery.
More Related Videos
05:45Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
Published on: January 7, 2019
10:26P. aeruginosa Infected 3D Co-Culture of Bronchial Epithelial Cells and Macrophages at Air-Liquid Interface for Preclinical Evaluation of Anti-Infectives
Published on: June 15, 2020
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities
Bioreactor Controls-II
Microbiota of the Respiratory Tract