Y Miyabara1, S Hashimoto, M Sagai
1National Institute for Environmental Studies, Ibaraki, Japan.
Abstract:
Vehicle exhaust particles from gasoline and diesel engine cars were analyzed for PCDDs and PCDFs. The congener patterns of PCDDs and PCDFs in exhaust particles were different between gasoline and diesel engine cars. Suspended particulate matter from electrostatic precipitator connected to a highway tunnel was also analyzed for PCDDs and PCDFs. The congener pattern of suspended particular matter was different from both of gasoline and diesel engine cars. Total amounts of PCDDs/PCDFs sum concentrations in gasoline, diesel and suspended particulate matter were 0.21, 0.87 and 26.0 ng/g, respectively. The I-TEQs levels in gasoline, diesel and suspended particulate matter were 4.2, 11 and 242 pg/g, respectively.