Endpoint of ECT-induced elevation in heart rate
Related Experiment Video
Updated: Aug 19, 2026

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
1Department of Psychiatry, Saint Louis University, Missouri 63104, USA.
Abstract:
Changes in the heart rate during electroconvulsive therapy (ECT) reflect seizure activity at a deeper brain site than shown by electroencephalography and motoric activity. Accordingly, such changes may provide additional information that is helpful in the evaluation of treatment quality. One basic measurement of heart rate change is the duration of ECT-induced tachycardia. In a prospective study, the electrocardiographic ECT records of 24 patients were rated for the abruptness of the endpoint of the seizure-induced elevation in heart rate; 19 showed abrupt endpoints and 5 showed gradual endpoints. The baseline heart rate of patients with abrupt endpoints (88 SD [standard deviation] 10 beats/min) was significantly lower (p = 0.00001) than those with gradual endpoints (118 SD 12 beats/min). A threshold occurred at a baseline heart rate of 100 beats/min, with abrupt endpoints below and gradual endpoints above. The data suggest that patients with low baseline heart rates might be likely to show bradyarrhythmia during the treatment, and corresponding precautions might be considered.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism, and...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes