Related Experiment Videos
Identification of inadequately cleaned equipment used in a sheep carcass-breaking process
1Agriculture and Agri-Food Canada, Research Centre, Lacombe, Alberta. GillC@em.agr.ca
Abstract:
Aeromonads deposited on pork during a carcass-breaking process were recovered on hydrophobic grid membrane filters placed on ampicillin-dextrin-ethanol agar. Isolates from 85 honey-yellow colonies from filters on that medium were Aeromonas hydrophila (95%) or Vibrio sp. (5%). Presumptive aeromonads, coliforms, and Escherichia coli in swab samples from product passing through a sheep carcass-breaking process were enumerated by hydrophobic grid membrane filtration techniques with a detection level of 1 CFU/100 cm2. Total aerobic counts were determined by a spread plate procedure with a detection level of 1 CFU/cm2 The numbers of aerobes, coliforms, and E. coli in the product were apparently unaffected by the carcass-breaking process, although coliforms and E. coli appeared to be redistributed from shoulder to loin and leg portions. However, the numbers of aeromonads on product increased by about two orders of magnitude as a result of the process. Few bacteria were recovered from most cleaned, large items of equipment, but aerobes, coliforms, and aeromonads were recovered at log total numbers of 5.25, 3.96, and 3.26, respectively, from most of 25 samples from bars supporting a conveyor belt. Also, aerobes, coliforms, E. coli, and aeromonads were recovered from 25 supposedly cleaned steel mesh gloves at log total numbers of 10.14, 5.54, 4.73, and 8.30, respectively. Those findings indicate that inspection of cleaned equipment and microbiological sampling of only food-contacting surfaces, as is the current practice at meat plants, cannot provide assurance that the cleaning of carcass-breaking equipment is adequate. Instead, enumeration of indicator organisms on product passing through a process seems to be required as well, with subsequent sampling of equipment to identify sources of contaminants if increases in numbers during processing are observed. For surety of adequate cleaning, enumeration of several types of indicator organism may be necessary, as increases during processing in the numbers of organisms that are present in relatively large numbers on product entering a process may be difficult to detect.
Insights
Aeromonads significantly increase during pork processing, indicating inadequate cleaning of equipment. Microbiological testing of products is crucial to ensure food safety and identify contamination sources.
Area of Science:
- Food Microbiology
- Food Safety
- Microbial Contamination
Background:
- Aeromonads are potential foodborne pathogens.
- Carcass-breaking processes can introduce microbial contamination.
- Current cleaning validation methods may be insufficient.
Purpose of the Study:
- To assess the impact of pork carcass-breaking on aeromonad levels.
- To evaluate the effectiveness of standard cleaning procedures in meat plants.
- To determine the role of equipment in microbial proliferation during processing.
Main Methods:
- Hydrophobic grid membrane filtration for enumerating aeromonads, coliforms, and Escherichia coli.
- Ampicillin-dextrin-ethanol agar for isolating Aeromonas hydrophila.
- Spread plate method for total aerobic counts.
- Sampling of product and equipment surfaces at various stages.
Main Results:
- Aeromonad numbers increased by two orders of magnitude during processing.
- Aeromonads, coliforms, and E. coli were recovered from inadequately cleaned equipment (conveyor belt bars and gloves).
- Aeromonads, coliforms, and E. coli levels on the product were not significantly affected by the process, but redistribution occurred.
- Standard inspection of cleaned equipment was insufficient to guarantee cleanliness.
Conclusions:
- Current cleaning and inspection practices in meat plants are inadequate to control aeromonad contamination.
- Microbiological monitoring of product during processing is essential to detect contamination.
- Targeted equipment sampling is necessary to identify and eliminate contamination sources when microbial loads increase.
- Enumeration of multiple indicator organisms may be required for comprehensive cleaning validation.