Effect of conductive hearing loss on the vestibulo-collic reflex
Related Experiment Video
Updated: Oct 20, 2026

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
1Department of Otolaryngology, Royal Hallamshire Hospital, Sheffield, UK.
Abstract:
The vestibulo-collic reflex represents a promising test for evaluating the integrity of otolith function. We have investigated the threshold of this response in a group of normal subjects, and the effect of a conductive hearing loss. A positive response was recorded in 31 of 32 normal subjects. The threshold of the vestibulo-collic reflex varied from 80 to 97 dBHL in these subjects with a 95% response rate at a threshold at 96 dBHL. A total of 23 ears with a conductive hearing loss in 17 patients were also investigated. The average conductive hearing loss (at 0.5, 1, 2 and 4 kHz) ranged from 8.75 to 40 dBHL (average 24.46 dBHL). A positive response was recorded in only two ears. Therefore, the vestibulo-collic reflex has a high stimulus threshold which is dependant on reliable transmission of the click stimulus to the inner ear thus limiting is clinical use.
Related Concept Videos
The Vestibular System
Equilibrium and Balance
Anatomy of the Ear
The Cochlea
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking the...
Auditory Perception