Consequences of static and pulsatile pressure on transmembrane exchanges during in vitro microdialysis: implication
E M Siaghy1, B Oesterlé, A Kheiri
1Laboratoire de chirurgie expérimentale, UPRES 971068, Faculté de Médecine, Université Henri Poincaré, Nancy, France.
Abstract:
Microdialysis is an established technique for measuring the kinetics of various neurotransmitters within the extracellular space in the field of neurochemistry. Recently, its use has been extended to sampling in other tissues, including liver, kidney and the heart. A persistent problem in cardiac microdialysis concerns two parameters related to myocardial function: pressure and frequency (heart rate). The aim of the study is to evaluate the consequences of pressure and frequency on transmembrane exchanges. Linear flexible microdialysis probes (membrane length: 12 mm, outside diameter: 390 microns, MWCO 50,000 Daltons) were designed in our laboratory. The probes, perfused at 2 microL/min with sterile water, were placed in a system filled with a glucose solution (2 g/L) and able to generate either static: 0 to 400 mmHg (0 to 53.31 kPa) or pulsatile pressure: 0-100; 0-200; 0-300 mmHg (0-13.32; 0-26.65; 0-39.98 kPa) at different frequencies: 1, 2 and 3 Hz. At 2 mu litre min-1 perfusion rate, the pressure inside the probe is estimated to be 80 mmHg (10.66 kPa). Under static pressure conditions, the glucose recovery rate can be expressed as an exponential function, and the outflow rate can be expressed as a linear function of the external pressure level. Under dynamic conditions, the external mean pressure must be accounted for. When external mean pressure exceeds 80 mmHg (10.66 kPa) (pressure generated by the flow rate of perfusion inside the probe), the recovery rate increases with frequency. Conversely, if the outer mean pressure is lower than 80 mmHg (10.66 kPa), the recovery rate decreases with frequency. Theoretical and experimental modelling results in a nomogram that can be used to estimate in vivo recovery. In conclusion, mass transfer across a microdialysis membrane is dependent on the direction of the transmembrane pressure gradient and increases with heart rate. These findings must be taken into account when in vivo recovery rates during cardiac microdialysis are determined.
Related Concept Videos
Dialysis
Fluid Movement Between Compartments