Related Experiment Video
Updated: Aug 19, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Do fire-fighters develop specific ventilatory responses in order to cope with exercise whilst wearing self-contained
1Sports Medicine and Human Performance Unit, Applied Physiology Research Group, School of Sports and Exercise Sciences, University of Birmingham, Edgbaston, UK.
Abstract:
In the present study we compared the ventilatory performance whilst wearing self-contained breathing apparatus (SCBA) during exercise, of a group of male fire-fighters (FF, n = 8), with a matched group of male civilians (CV, n = 7). The mean (SEM) physiological characteristics of the subjects (FF vs CV) were: age 31 (2) years vs 32 (4) years; height 179 (2) cm vs 183 (3) cm, P < 0.05; mass 80 (2) kg vs 84 (3) kg; maximum oxygen uptake 4.52 (0.14) 1 x min(-1) vs 4.39 (0.27) 1 x min(-1). Volunteers performed a 23-minute fire-fighting simulation (Firetest), without and with SCBA (Fire-fighter II, Siebe-Gorman/North Safety, Cheshire, UK). During SCBA wear, the FF group used significantly less air and rated their breathlessness significantly lower than the CV group. The mean tidal volume (V(T)) of the FF group remained constant between non-SCBA and SCBA wear conditions, but the CV group increased their mean V(T) by 18%, (P < 0.01). There were no significant between-group differences during the Firetest in total breath duration, inspiratory or expiratory duration, breathing frequency (fb), or heart rate. These data suggest that the respiratory responses of firefighters while wearing SCBA, which are characterised by increases in (fb) but not V(T), may help to reduce their breathlessness during exercise while wearing SCBA.
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Hyperpnea and Hyperventilation