Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
An in vivo comparison of a catheter mounted pressure transducer system with conventional balloon catheters
I M Stell1, S Tompkins, A T Lovell
1Accident & Emergency Dept, King's College Hospital, London, UK.
Abstract:
In the assessment of respiratory muscle function balloon catheters have been widely used for pressure measurements. However, this type of investigation is poorly tolerated by acutely ill patients. This study assessed the performance of a possible alternative, a catheter-mounted miniature pressure transducer (CMT). The assessment consisted of a laboratory study of the linearity, frequency response, and stability of gain and baseline of the CMT system, and an in vivo study directly comparing the CMT and balloon catheter systems in seven normal subjects for a range of respiratory manoeuvres. These were: 1) maximal inspiratory and expiratory pressures against a closed airway, 2) twitch transdiaphragmatic pressure elicited by cervical magnetic phrenic nerve stimulation, and 3) tidal breathing, sniffs and coughs in five body positions. The agreement of the two systems was analysed for measurements of 1) absolute pressures, 2) magnitude of changes in pressure, and 3) rate of change of pressure (maximum relaxation rate after sniff manoeuvres). The CMT system was linear, with a high frequency response and stable gain, but showed baseline drift. The two systems agreed well for measurements of change and rate of change of pressure, but less well for measurements of absolute pressure. The CMT system tested is potentially useful for studies of acute changes in respiratory pressures, or studies of respiratory muscle strength, but would be less useful where accurate measurements of absolute pressures are required.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: