Related Experiment Video
Updated: Jul 10, 2026

05:52
Observation and Analysis of Blinking Surface-enhanced Raman Scattering
Published on: January 11, 2018
Radar and optical observations of asteroid 1998 KY26
1Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109-8099, USA. Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-25165 Ond&rbreve;ejov, Czech Republic. School of Electrical Engineering and.
Summary
Near-Earth asteroid 1998 KY26 spins exceptionally fast, with a rotation period of only 10.7 minutes. This rapid spin suggests it is a single, solid object, not held together by gravity alone.
Area of Science:
- Planetary Science
- Asteroid Research
- Near-Earth Objects
Background:
- Near-Earth asteroids (NEAs) are crucial for understanding solar system evolution.
- Rapidly rotating objects provide insights into material strength and formation processes.
Purpose of the Study:
- To characterize the physical properties of the newly discovered NEA 1998 KY26.
- To investigate the implications of its rapid rotation on its structure and origin.
Main Methods:
- Photometric observations shortly after discovery.
- Analysis of asteroid shape, size, composition, and rotation period.
Main Results:
- NEA 1998 KY26 is a ~30-meter, slightly elongated spheroid.
- Its composition is similar to carbonaceous chondrites.
- It exhibits an unprecedented rotation period of 10.7 minutes.
Conclusions:
- The rapid rotation indicates 1998 KY26 is a monolithic body, not a rubble pile.
- It likely originated as a fragment from a larger asteroid's destruction.
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...

