Study of arterial blood pressure by a Windkessel-type model: influence of arterial functional properties
B Diourté1, J P Siché, V Comparat
1CNRS IN2P3, Grenoble, France.
Objective:
To analyse the performance of a Windkessel blood pressure (BP) modeling of arterial compliance adjusted in a dynamic fashion according to a non-linear relationship between the arterial compliance (AC) and BP. Non invasive measurements of the radial BP waveform (MILLAR tonometry) were compared to those constructed by an electric simulator reproducing the model in a symmetrical network subdivided into 121 segments. We introduced at cardiac level the aortic stroke volume (Doppler echocardiography) and the dynamic values of compliance (relation of compliance-to pressure, constant or variable) whether the model was linear or non linear, measured by high resolution Doppler (NIUS 02) for each subject.
Results:
At the radial artery segment the modelled BP obtained by the non linear model of AC was not significantly different from the measured BP wave, while in the linear model (AC constant at mean BP level) the systolic BP was significantly underestimated. (*P < 0.05).
Conclusion:
This work shows the limits inherent in simplification of arterial compliance in the Windkessel model using constant parameters. This demonstrates the influence of the dynamic properties of the arterial wall in a conduction artery on the level of systolic and diastolic BP.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Blood Pressure
Measurement of Blood Pressure
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.