Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Aortic Regurgitation IV: Nursing Management01:17

Aortic Regurgitation IV: Nursing Management

304
A nurse managing a patient with aortic regurgitation begins with a comprehensive assessment, including a review of the patient's medical history, family history, and lifestyle factors. During the cardiac examination, the nurse listens for heart sounds and checks for signs of valve abnormalities. The nurse also observes for symptoms such as dyspnea, orthopnea, and paroxysmal nocturnal dyspnea and assesses the patient's endurance and daily activity tolerance.Based on the findings, the nurse...
304
Aortic Regurgitation III: Medical Management01:25

Aortic Regurgitation III: Medical Management

423
Aortic regurgitation (AR) is when the aortic valve does not close or seal properly, leading to backward blood circulation from the aorta into the left ventricle during diastole. Common causes of AR include rheumatic heart disease, congenital valve defects, and aortic root dilation. Managing AR requires a multifaceted approach to alleviate symptoms, preserve left ventricular function, and address the underlying cause of the regurgitation. Patients with symptomatic AR or significant left...
423
Aortic Regurgitation I: Introduction01:15

Aortic Regurgitation I: Introduction

554
IntroductionAortic regurgitation is characterized by the backward flow of blood from the aorta into the left ventricle during diastole and arises from the improper closure of the aortic valve. This condition results in left ventricular volume overload and can stem from both acute and chronic etiologies, each contributing uniquely to the disease's progression and symptomatology.Acute and Chronic CausesAcute aortic regurgitation often results from events that suddenly impair the integrity of the...
554
Aortic Regurgitation II: Clinical Features and Diagnostic Tests01:22

Aortic Regurgitation II: Clinical Features and Diagnostic Tests

462
Aortic valve regurgitation (AR) occurs when the aortic valve fails to close properly, allowing blood to flow backward from the aorta into the left ventricle. This backflow can result in two distinct clinical presentations: acute and chronic AR, each characterized by its own set of symptoms and physical findings.Acute Aortic RegurgitationAcute AR presents with a sudden onset of severe symptoms. Patients typically experience profound dyspnea (shortness of breath), chest pain, and signs of left...
462
Global Climate Change01:50

Global Climate Change

28.8K
Throughout its ~4.5 billion year history, the Earth has experienced periods of warming and cooling. However, the current drastic increase in global temperatures is well outside of the Earth’s cyclic norms, and evidence for human-caused global climate change is compelling. Paleoclimatology, the study of ancient climate conditions, provides ample evidence for human-caused global climate change by comparing recent conditions with those in the past.
28.8K
Work Done During Volume Change01:17

Work Done During Volume Change

5.1K
In mechanics, work is done on an object when the force acting on it displaces the object. In thermodynamics, work done on a system can be estimated when the system's volume changes during any thermodynamic process.
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
5.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Deformation of the moving magnetic skyrmion lattice in MnSi under electric current flow.

Communications physics·2024
Same author

Precise Measurement of Differential Cross Sections of the Σ^{-}p→Λn Reaction in Momentum Range 470-650  MeV/c.

Physical review letters·2022
Same author

Observation of Coulomb-Assisted Nuclear Bound State of Ξ^{-}-^{14}N System.

Physical review letters·2021
Same author

Swelling of Doubly Magic ^{48}Ca Core in Ca Isotopes beyond N=28.

Physical review letters·2020
Same author

The Short-term Outcomes of Neovalve Deep Venous Reconstructive Surgery.

Journal of vascular surgery. Venous and lymphatic disorders·2016
Same author

Variant parameter values-as defined by the Chicago Criteria-produced by ManoScan and a new system with Unisensor catheter.

Neurogastroenterology and motility·2014

Related Experiment Video

Updated: Jan 25, 2026

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
04:56

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm

Published on: August 1, 2025

494

Will endoluminal aortic grafting change aortic surgery?

S Hoshino

    Annals of Thoracic and Cardiovascular Surgery : Official Journal of the Association of Thoracic and Cardiovascular Surgeons of Asia
    |August 14, 1999
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
    14:14

    Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

    Published on: December 11, 2017

    14.6K
    Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
    12:17

    Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

    Published on: May 21, 2017

    11.8K

    Related Experiment Videos

    Last Updated: Jan 25, 2026

    Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
    04:56

    Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm

    Published on: August 1, 2025

    494
    Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
    14:14

    Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

    Published on: December 11, 2017

    14.6K
    Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
    12:17

    Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

    Published on: May 21, 2017

    11.8K