Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
Related Experiment Video
Updated: Oct 19, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
S G Sakka1, K Reinhart, A Meier-Hellmann
1Department of Anaesthesiology and Intensive Care Medicine, Friedrich-Schiller-University of Jena, Bachstrasse 18, D-07 740 Jena, Germany.
Objective:
We studied the agreement between cardiac output measurements via pulmonary artery thermodilution [CO(PA)], regarded as the current clinical gold standard, and aortic transpulmonary thermodilution [CO(AORTA)].
Design:
Prospective clinical study.
Setting:
Surgical intensive care unit of a university hospital.
Patients:
37 patients with sepsis or septic shock (n = 34) and subarachnoid haemorrhage (n = 3).
Measurements And Results:
We analysed 449 simultaneous cardiac output measurements. All patients were deeply sedated and mechanically ventilated in a pressure controlled mode. Each patient received a 7.5-F five-lumen pulmonary artery catheter and a 4-F aortic catheter with an integrated thermistor. The thermistors of the two different catheters were connected to one computer system (COLD-Z021, Pulsion Medical Systems, Munich, Germany). Linear regression analysis revealed: CO(AORTA) = 0.96. CO(PA) + 1.02 (l/min) (r = 0.97, p < 0.0001). CO(AORTA) was consistently higher than CO(PA) with a bias of 0.68 (l/min) and a standard deviation of 0.62 (l/min).
Conclusion:
Cardiac output derived from aortic transpulmonary thermodilution is suitable for measurement in the intensive care unit. Measurements of CO(AORTA) are consistent with, but slightly higher than, those obtained from pulmonary artery thermodilution.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...