Lavage-induced Surfactant Depletion in Pigs As a Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: September 7, 2016
Reduced ventilator pressure and improved P/F ratio during percutaneous arteriovenous carbon dioxide removal for
S K Alpard1, J B Zwischenberger, W Tao
1Department of Surgery, University of Texas Medical Branch and Shriners Burns Institute, Galveston 77555-0528, USA.
Objective:
To evaluate the effect of percutaneous arteriovenous carbon dioxide removal (AVCO2R) on ventilator pressures and P/F ratio in a clinically relevant large-animal model of severe respiratory failure.
Summary Background Data:
AVCO2R was developed as a simple arteriovenous shunt with a commercially available low-resistance gas exchange device of sufficient surface area for near-total CO2 removal. With an AV shunt 10% to 15% of cardiac output, AVCO2R allows a reduction in ventilator airway pressures without hypercapnia or the complex circuitry and monitoring required for conventional ECMO.
Methods:
AVCO2R was applied to a new, clinically relevant large-animal model of severe respiratory failure created by smoke inhalation and cutaneous flame bum injury. Adult sheep (n = 9, 38+/-6 kg) received a 40% total body surface area, third-deinsufflation. After injury, all animals were placed on volume-controlled mechanical ventilation to achieve PaO2 > 60 mmHg and PacO2 < 40 mmHg. Animals were placed on AVCO2R within 40 to 48 hours of injury when the PaO2/FiO2 was <200. Animals underwent cannulation of the carotid artery and jugular vein with percutaneous 10F arterial and 14F venous cannulas. Shunt flow was continuously monitored using an ultrasonic flow probe and calculated as a percentage of cardiac output.
Results:
AVCO2R flows of 800 to 900 ml/min (11% to 13% cardiac output) achieved 77 to 104 ml/min of CO2 removal (95% to 97% total CO2 production) while maintaining normocapnia. Significant reductions in ventilator settings were tidal volume, 421.3+/-39.8 to 270.0+/-6.3 ml; peak inspiratory pressure, 24.8+/-2.4 to 13.7+/-0.7 cm H2O; minute ventilation, 12.7+/-1.4 to 6.2+/-0.8 L/min; respiratory rate, 25.4+/-1.3 to 18.4+/-1.8 breaths/min; and FiO2, 0.88+/-0.1 to 0.39+/-0.1. The P/F ratio increased from 151.5+/-40.0 at baseline to 320.0+/-17.8 after 72 hours.
Conclusions:
Percutaneous AVCO2R allows near-total CO2 removal and significant reductions in ventilator pressures with improvement in the P/F ratio.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)