M Bovenzi1, C J Lindsell, M J Griffin
1Institute of Occupational Medicine, University of Trieste, Italy. bovenzi@univ.trieste.it
Objectives:
Changes in finger circulation were studied during and after acute exposure to increasing magnitudes of hand-transmitted vibration.
Methods:
Finger skin temperature (FST) and finger blood flow (FBF) were measured in the middle fingers of both hands of 10 healthy men. The right hand was exposed for 15 minutes to 125-Hz vibration with acceleration magnitudes of either 5.5, 22, 44, or 62 m/s2 root-mean-square. The measures of finger circulation were taken before the vibration, at fixed intervals during exposure, and during a 45-minute recovery period.
Results:
The FST did not change during vibration exposure, whereas vibration of any magnitude provoked significant reductions in the FBF of the vibrated finger when compared with the preexposure FBF and the contralateral (nonvibrated finger) FBF. Vasoconstrictor aftereffects (i.e., during recovery) were observed in both fingers after the end of exposure to vibration magnitudes greater than 22 m/s2 root-mean-square. The higher the vibration magnitude, the stronger the reduction of FBF in either finger during both vibration exposure and the recovery period. This effect was stronger in the vibrated finger than in the nonvibrated finger during both periods.
Conclusions:
Acute exposure to 125-Hz vibration can reduce FBF in both the vibrated and the nonvibrated finger, and the degree of digital vasoconstriction is related to the magnitude of the vibration. The pattern of the hemodynamic changes during and after vibration exposure suggests that complex vasomotor mechanisms are involved in the response of digital vessels to acute vibration.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection