Related Experiment Video
Updated: Jul 15, 2026

An Inverse Analysis Approach to the Characterization of Chemical Transport in Paints
Published on: August 29, 2014
An evaluation of worker lead exposures and cleaning effectiveness during removal of deteriorated lead-based paint
1National Institute for Occupational Safety and Health, Cincinnati, Ohio, USA.
Abstract:
We evaluated worker lead exposures and cleaning effectiveness during initial cleanup of 19th-century buildings with highly deteriorated lead-based paint. Eighteen rooms of similar size and condition in two university-owned buildings were selected for a pilot project to compare three methods for removing loose paint, paint chips, and dust. The methods used were: dry scraping followed by dry sweeping (no engineering or work practice controls); wet scraping and high-efficiency particulate air (HEPA) vacuuming; and the latter method with the addition of a portable HEPA-filtered exhaust fan in the room providing about 40 air changes per hour. The final step for all methods was wet-mopping once with tri-sodium phosphate solution. During a single day 18 rooms were cleaned; each of three two-person work crews cleaned six rooms, two with each method. Air and surface samples were collected before, during, and after cleaning. All of the methods were potentially hazardous to workers: 44 percent of the method-based exposures (range: 5.0-360 micrograms/m3) and one of five full-shift exposures exceeded the OSHA PEL (range 9.4-110 micrograms/m3). Lowest worker exposures were during the wet scraping and vacuuming method (mean: 24 micrograms/m3). Providing general ventilation in rooms did not reduce worker exposures and appeared to increase them (mean: 73 micrograms/m3). Overall, the mean floor surface lead levels were reduced 50 percent after cleaning (from 2,600 to 1,300 micrograms/ft2), but the effectiveness of the three methods in reducing floor lead levels did not differ significantly. Overall, the method, mean paint lead concentration, pre-cleaning surface lead concentration, and work crew were significantly associated with the mean worker exposures during cleaning (p = 0.023), but not with the post-cleaning surface lead concentrations (p = 0.13).
More Related Videos
Related Concept Videos
Nursing Process for Patient and Caregiver Teaching III: Evaluation and Documentation
Nurses can use several methods to evaluate patient outcomes. For example, oral questions can assess cognitive learning, patient...
Washing, Drying, and Ignition of Precipitates
Deleterious Substances in Aggregate
Another type of impurity is clay and fine material that...