Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart
Related Experiment Video
Updated: Oct 19, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
1First Department of Surgery, Hiroshima University School of Medicine, Minamiku, Japan. hwada@mcai.med.hiroshima-u.ac.jp
Abstract:
We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial shunt to achieve left-right balance. We have conducted numerical simulation, a mock test, and an acute animal experiment to analyze left-right heart balance during ERTAH operation. Numerical simulation was performed under conditions in which the flow of the left artificial heart was fixed at 6 L/min, the flow of the right artificial heart was varied from 4.8 to 6 L/min, and the interatrial resistance was also varied. The relationship between the interatrial shunt flow rate and the output of the left and right artificial hearts was balanced when the flow of the right artificial heart was at 5.45 L/min. In a mock test, 2 DeBakey roller pumps were connected to the left and right sides of a Donovan mock circulatory system, and an interatrial shunt was created between the inlet ports of the left and right roller pumps. The interatrial resistance of the mock system was varied from 7.7, to 4.3, and to 2.9 mm Hg x min/L when the inner diameter of the interatrial shunt was 6, 8, and 10 mm, respectively. As in the mock test, 2 roller pumps were used to bypass the right and left hearts of a goat weighing 60 kg. The flow rate of the left heart was almost constant (4.7 L/min). The flow of the right heart was approximately 4.1 L/min when the interatrial shunt flow rate was zero. A leading consideration was that the left to left shunt through the bronchial arteries in this goat was approximately 0.6 L/min. In developing the ERTAH, we considered that creating an interatrial shunt between the inlet ports of the ERTAH as well as making a difference between the chamber volumes might be effective in balancing the left-right sides of the artificial heart.
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...