Related Experiment Video
Updated: Oct 19, 2026

A New Straightforward Method for Lipophilicity (logP) Measurement using 19F NMR Spectroscopy
Published on: January 30, 2019
Comparative study of hydrocarbon, fluorocarbon, and aromatic bonded RP-HPLC stationary phases by linear solvation
1Department of Chemistry, University of Minnesota, Minneapolis 55455, USA.
Abstract:
The retention properties of eight alkyl, aromatic, and fluorinated reversed-phase high-performance liquid chromatography bonded phases were characterized through the use of linear solvation energy relationships (LSERs). The stationary phases were investigated in a series of methanol/water mobile phases. LSER results show that solute molecular size and hydrogen bond acceptor basicity under all conditions are the two dominant retention controlling factors and that these two factors are linearly correlated when either different stationary phases at a fixed mobile-phase composition or different mobile-phase compositions at a fixed stationary phase are considered. The large variation in the dependence of retention on solute molecular volume as only the stationary phase is changed indicates that the dispersive interactions between nonpolar solutes and the stationary phase are quite significant relative to the energy of the mobile-phase cavity formation process. PCA results indicate that one PCA factor is required to explain the data when stationary phases of the same chemical nature (alkyl, aromatic, and fluoroalkyl phases) are individually considered. However, three PCA factors are not quite sufficient to explain the whole data set for the three classes of stationary phases. Despite this, the average standard deviation obtained by the use of these principal component factors are significantly smaller than the average standard deviation obtained by the LSER approach. In addition, selectivities predicted through the LSER equation are not in complete agreement with experimental results. These results show that the LSER model does not properly account for all molecular interactions involved in RP-HPLC. The failure could reside in the V2 solute parameter used to account for both dispersive and cohesive interactions since "shape selectivity" predictions for a pair of structural isomers are very bad.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...