Thermal thresholds, vibrotactile thresholds and finger systolic blood pressures in dockyard workers exposed to
1Human Factors Research Unit, Institute of Sound and Vibration Research, University of Southampton, Southampton SO17 1BJ, UK. cl@isvr.soton.ac.uk
Objectives:
To quantify neurological dysfunction in workers exposed to hand-transmitted vibration using alternative neurological tests. To relate the neurological findings to the results of vascular tests and the symptoms reported by subjects with vibration-induced white finger.
Methods:
Thermal thresholds (for perception of heat and cold), vibrotactile thresholds (for perception of vibration at 31.5 and 125 Hz) and finger systolic blood pressures were measured in 107 dockyard workers, including 31 controls and 76 workers exposed to hand-transmitted vibration (50 reporting finger blanching consistent with vibration-induced white finger). A history of vibration exposure and symptoms associated with hand-transmitted vibration were obtained for each subject.
Results:
Increased duration of exposure to vibration resulted in a deterioration of both thermal thresholds and vibrotactile thresholds. Finger systolic blood pressures were lower in subjects reporting finger blanching and were related to the extent of blanching on the measured finger. Reported sensations of tingling were not correlated with any of the threshold measures; thermal thresholds and vibrotactile thresholds showed evidence of deterioration with reports of increasing numbness. Both numbness and tingling were correlated with reports of finger blanching. Finger systolic blood pressures were not correlated with either thermal or vibrotactile thresholds.
Conclusions:
Vascular and neurological signs produced by hand-transmitted vibration can occur independently, but the principal vascular symptom (i.e. attacks of blanching) and some commonly reported neurological symptoms (i.e. sensations of numbness and tingling) may be related.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...